Lewden RCBO-16/30/SPA 1 Module Single Pole B Curve Type A RCBO 16A 6kA 30mA
RCBO-16/30/SPA
16kA - B Type 30mA RCBOs - 1 Pole + Unswitched Neutral. Residual current circuit breaker with integral overcurrent protection.
The Lewden range of circuit protection devices are designed and tested for use with Lewden branded distribution boards.
Single module RCBOs are suitable for use in TN-S,TN-C-S, & TT * network systems. (* when used in conjunction with a 2 pole mains isolation switch). Note that alone, single pole RCBOs are not considered as a suitable means of isolation on systems with IT & TT earthing arrangements, where it may be necessary to disconnect the neutral connection in order to achieve safe isolation of individual circuits.
Technical Info:
Reference standard: IEC /BS EN61009-1
Rated Voltage (Un): 230-240V ac
Rated Current (In): 6-50A
Rated Frequency (Fn): 50/60Hz
Rated short circuit capacity: 6kA
Rated impulse withstand (Uimp): 4kV
Tripping Characteristic: B or C
Rated residual current: 30mA
Neutral pole: Un-switched
Terminals line/load: 1-16mm²
Neutral conductor length: 360mm (can be cut to suit)
Terminal ghtening torque: 2.5Nm
Operating temperature: -5 to +40°c
Reference calibration temp.: +30°c
RCCB / RCBO OPTIONS
Lewden RCCBs and RCBOs are available in both type AC and type A versions, offering the installer the option to choose the correct protection device for the load application. The range also includes 100A rated RCCBs in type A, in 30mA and 100mA time delayed versions.
Protection against overcurrent
RCCBs do not provide protection against overload or short circuits. They must be used in conjunction with MCB devices to provide circuit protection against overloads and short circuit faults.
Power supply polarity
Lewden type A & AC RCCBs are not polarity sensitive. The devices can be mains fed from either the upper or lower terminal sets. On 2 pole devices, Line and Neutral connections can be transposed to either to the left or right (e.g. Line IN/OUT can be made on either pole 1-2 or 3-4) On 4 pole devices, Line and Neutral connections must be strictly terminated according to the terminal markings on the device. 4P devices are suitable for use in circuits with and without a neutral supply connection (3 and 4 wire systems), due to the integral test circuit being connected between two of the phases.
Earth system
RCCBs are suitable for use in TN-S,TN-C-S, & TT network systems. Where used within a split load consumer unit installed in domestic premises forming part of a TT network, the double pole main switch of the consumer unit should incorporate an S type time delayed RCCB, e.g. 100mA S type RCCB
Ean Code | 5026992048672 |
Trip Type | B Curve Type A |
Short Circuit Rating | 6kA |
Cable Capacity | 16 mm2 |
Sensitivity | 30 mA |
Rcd Type/class | A |
Product | RCBO |
Type | Single Pole |
Voltage | 230 V |
Unit Weight | 0.167 kg |
Pole Configuration | SP+N |
Mounting | DIN Rail |
Width | 18 mm |
Depth | 76 mm |
Current Rating | 16A |
Standards | BS EN 61009-1 |
Ce Approved | N |
Rcd Sensitivity | 30 mA |
Number Of Poles | Single Pole (1P) |
Height | 114 mm |
Number Of Modules | 1 |
Delivery Costs
Our standard delivery charge to UK mainland addresses is £5.90 ex-VAT.
Take advantage of FREE* Delivery when you spend over £100 (per order) ex-VAT.
*Delivery charges to JE, GY, TR, BT, IM, IV, HS, KW, ZE and certain PA post codes are £12.00 ex-VAT.
Solar Panels, Batteries and Inverters
Due to their size all solar panels, batteries and inverters orders up to 50 qty will be despatched on a pallet and incur a £120** ex-VAT delivery charge.
**£180 ex VAT to JE, GY, TR, BT, IM, IV, HS, KW, ZE and certain PA post codes.
Click here to find out more.