Hager VMLF910C Design10 18th Edition All Metal 10 Way Flush Mounting Twin RCD Flexible Split Load Consumer Unit With 100A Switch Disconnector Isolator & 2 x 100A 30mA Type A RCDs

VMLF910C

1 in stock for next day delivery see cut off times
£166.96 inc Vat
£139.13 ex Vat
Free delivery for orders over £100 ex VAT
Design 10 has been created as an entry level board which meets the requirements of the wiring regulations (BS 7671) and allows the consumer unit to be installed flush at the height stated in the building regulations (Part M), with minimum impact on the area.
Description
Features

• Cable clamp - Secures supply cables on entry to main incoming device preventing any movement being transmitted through meter tails to device
• Rear Knockouts for ease of cable entry – Cable protector plate (VM02CE) provided
• 2 piece base allows for first fix, second fix option
• Adjustable Depth Base - Base assembly is adjustable from 72mm to 92mm, at 72mm allows for 60mm studwork and 12mm plasterboard
• Full metal DIN rail – Secure and stable attachment of devices
• Quick release clip on MCB/RCBO – Allows removal of MCB/RCBO with busbar still in place
• Optimised cabling space – DIN rail position allows maximum cabling space
• Top mounted terminal rail makes the wiring of the neutral and earth connections neat and simple.
• Torque settings displayed inside front cover so they're easily accessible by the electrician.


Technical Specification

Standards:
BS EN 61439-3
Classification: Consumer Unit
Rated & Operational Voltage (Un/Ue): 230V a.c 50 Hz
Rated Insulation Voltage (Ui ): 320V a.c. 50Hz
Rated Frequency (fn): 50 Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated Current of the Assembly (Ina): 100A
Rated Current of an Outgoing Circuit InC: MTN1** MCB (Marked Rated Current on Device)
Pollution Degree: 2
Intended use: Intended for use in domestic (residential) or similar premises
Electromagnetic compatibility (EMC) classification: EMC environment B
External design: Wall mounted, surface type, enclosed assembly.
Mechanical impact protection: IK05
Type of construction: Fixed parts
Incoming Line/Neutral terminal (80 - 100A board): 50mm²
Incoming Earth Terminal: 16mm²
Technical Information
Rcd 2 Rating 100 A
Ean Code 5015652602026
Range Hager Design10
Sensitivity 30 mA
Product Consumer Unit w/ Main Switch + RCD
Ingress Protection IP3X
Voltage 230 V
Pole Configuration Single Pole (1P)
Mounting Flush
Width 335 mm
Depth 72 mm
Current Rating 100A
Standards BSEN61439-3
High Integrity No
Rcd Rating 100 A
Rcd Sensitivity 30 mA
Number Of Poles Single Pole (1P)
Height 282 mm
Door/lid Type Solid
Rcd 2 Sensitivity 30 mA
Body Colour White
Body Material Steel
Outgoing Ways 10 Way
Incomer Included Y
Incomer Current Rating 100 A
Metered N
Split Load Y
Rcd S Included Y
Number Of Rcd S 2
Outgoing Devices Included N
18th Edition Compliant Y
Delivery

Delivery Costs

Our standard delivery charge to UK mainland addresses is £5.90 ex-VAT.

Take advantage of FREE* Delivery when you spend over £50 (per order) ex-VAT.

*Delivery charges to JE, GY, TR, BT, IM, IV, HS, KW, ZE and certain PA post codes are £12.00 ex-VAT.

Solar Panels, Batteries and Inverters

Due to their size all solar panels, batteries and inverters orders up to 50 qty will be despatched on a pallet and incur a £120** ex-VAT delivery charge.

**£180 ex VAT to JE, GY, TR, BT, IM, IV, HS, KW, ZE and certain PA post codes.

Click here to find out more.

Reviews

You May Also Need