What Size Trunking Do I Need? A Practical Guide

By:

Published: 21 Sep 2026 Share: Facebook, Twitter

Choosing electrical trunking can seem straightforward until you start looking at the number of sizes available. Do you need 16mm x 16mm mini trunking, something larger such as 50mm x 25mm or is the job better suited to maxi trunking?

The answer depends primarily on the cables you need to contain. Their number, size and type all affect how much space is required, along with the route the trunking needs to follow and whether more cables may be added later.

Here are the main things to consider before choosing your trunking size.

How Are Trunking Sizes Measured?

Electrical trunking is normally described by its width and depth.

For example, 25mm x 16mm trunking is approximately 25mm wide and 16mm deep, while a larger 50mm x 50mm system provides considerably more internal capacity.

It is important to remember that these dimensions describe the trunking itself. The usable internal space can differ because of the thickness and design of the trunking, lid and any internal dividers.

This means two systems with similar external dimensions may not necessarily provide exactly the same usable cable space.

Start With the Cables

The most important question is not how much room you have on the wall. It is how many cables need to go inside the trunking.

Consider:

  • The number of cables

  • The diameter or dimensions of each cable

  • The type of cable

  • Whether different cable types are being installed

  • Whether additional cables may be required later

A small run containing one or two relatively small cables may only require compact mini trunking. A route containing several cables will require significantly more space.

Trying to squeeze cables into the smallest trunking they will physically fit inside is not a good way to select a size.

There needs to be sufficient room for the cables to be installed without excessive crowding or damage.

How Full Can Electrical Trunking Be?

Cable capacity is one of the most important parts of trunking selection.

For common cable and trunking combinations, industry guidance provides cable and trunking factors that can be used to determine appropriate capacity.

For other cable or trunking sizes, guidance commonly uses a maximum space factor of 45% of the trunking's net internal cross-sectional area.

In simple terms, you should not assume that the entire internal area of the trunking is available to pack with cables.

Cable capacity also needs to be considered alongside factors such as current-carrying capacity, grouping and the requirements of the particular installation.

For this reason, cable quantities should be properly assessed rather than estimated by looking at whether another cable can physically be pushed beneath the lid.

When Is Mini Trunking Suitable?

PVC mini trunking is generally suited to smaller cable runs where relatively little capacity is required.

Common mini trunking dimensions include sizes such as:

  • 10mm x 8mm

  • 16mm x 10mm

  • 16mm x 16mm

  • 25mm x 16mm

  • 38mm x 16mm

  • 38mm x 25mm

  • 38mm x 38mm

  • 50mm x 25mm

The smaller sizes can work well for simple surface-mounted cable routes where only limited containment is required.

As the number or size of the cables increases, moving to a larger profile gives you more usable space and can make the installation easier to manage.

Mini trunking is particularly useful where you want the containment to remain relatively discreet rather than installing a large trunking system unnecessarily.

When Should You Consider Maxi Trunking?

There comes a point where trying to fit everything into mini trunking stops making sense.

PVC maxi trunking is designed for installations requiring greater capacity and is available in much larger dimensions.

Typical sizes include:

  • 50mm x 50mm

  • 75mm x 50mm

  • 75mm x 75mm

  • 100mm x 50mm

  • 100mm x 100mm

  • 150mm x 150mm

These larger sizes are useful when multiple cables need to follow the same route or when the installation requires considerably more internal space.

Maxi trunking can also offer more flexibility on installations that may need additional cables in the future.

The key is not to choose maxi trunking simply because bigger seems better. Oversized containment may take up unnecessary space and look out of proportion to the installation.

Choose a system that provides suitable capacity without going substantially beyond what the project requires.

Don't Forget Bends and Changes of Direction

Trunking capacity is not the only consideration.

You also need to think about how the cables will behave when the trunking turns a corner.

Cables have minimum bending requirements and should not be forced through an excessively tight change of direction simply because they fit comfortably within the straight section of trunking.

Look at the complete route before choosing your system.

If it includes internal bends, external bends, flat bends or tees, make sure the trunking and accessories provide a suitable route for the cables being installed.

This becomes increasingly important as cable sizes increase.

Allow for Future Cables

Another common mistake is sizing trunking for exactly what is being installed today.

Consider what might happen to the installation later.

An office may need more sockets. A workshop could gain another piece of equipment. A commercial unit might be rearranged for a new tenant.

If there is a realistic chance that another cable will need to follow the same route, providing sensible spare capacity at the initial installation can be much easier than replacing an entire trunking run later.

That does not mean automatically choosing the largest size available. It simply means thinking beyond the immediate cable requirement.

Check Your Accessories Before Ordering

Once you have chosen a trunking size, check that the fittings required for the route are available in the same system.

Depending on the installation, you may need:

  • Internal or external bends

  • Flat bends

  • Tees

  • Couplers

  • End caps

  • Dividers

  • Reducers

  • Mounting boxes

A 25mm x 16mm trunking run, for example, should be planned with compatible 25mm x 16mm accessories rather than relying on improvised connections between different systems.

Planning the fittings at the same time as the trunking can make installation considerably easier.

So What Size Trunking Do You Need?

There is no single trunking size that is right for every electrical installation.

Start by identifying the cables you need to contain, then calculate or check the required capacity rather than simply selecting the smallest trunking they appear to fit inside.

For smaller cable routes, PVC mini trunking provides a wide choice of compact dimensions. Where cable numbers or sizes increase, larger mini trunking or maxi trunking may be more appropriate.

Consider the entire route too, including bends, branches, accessories and any realistic need for additional cabling in the future.

Taking a little more time to choose the correct size at the beginning can result in a neater installation and avoid discovering halfway through the job that the trunking you bought is simply too small.

Explore our full range of Electrical Trunking to compare different trunking sizes along with the bends, tees, couplers, end caps and other accessories required to complete your installation.