MK Sentry H5760S 2 Module Double Pole Residual Current Device RCD 63A 230V 100mA Type AC

H5760S

Est 3-4 day delivery (Subject to availability)
£64.67 inc Vat
£53.89 ex Vat
Free delivery for orders over £100 ex VAT

MK Sentry H5760S Double Pole RCD – Type AC, 63A, 100mA, 2 Module for Sentry Consumer Units

The MK Sentry H5760S is a 2 Module Type AC Residual Current Device (RCD) rated at 63A with a 100mA trip sensitivity. Designed for use in MK Sentry Consumer Units and compatible enclosures, it provides essential earth leakage protection and complies with 17th Edition IEE Wiring Regulations. Ideal for installations where higher trip thresholds are required.

  • Type AC RCD: Detects standard alternating current (a.c.) earth leakage faults, suitable for general-purpose protection.
  • Double Pole Switching: Ensures safe disconnection of both live and neutral conductors for full isolation and fault protection.
  • 100mA Sensitivity: Suitable for applications where a higher trip threshold is necessary, such as lighting circuits or fire alarm systems.
  • Compliance with Regulations: Provides positive contact status indication in line with 17th Edition IEE Wiring Regulations (537.2.2.2 & 537.3.2.2).
  • Flexible Installation: Compatible with MK Sentry Consumer Units and 2- or 4-module enclosures for easy integration.
Technical Specification
  • Type: Type AC RCD
  • Current Rating: 63A
  • Tripping Current: 100mA
  • Voltage: 230V
  • Poles: Double Pole
  • Modules: 2
  • Cable Capacity: Up to 50mm²
  • Dimensions: 85 x 36 x 75mm
  • Standard: BS EN 61008: 1995

Choose the MK Sentry H5760S RCD for dependable 100mA protection in installations requiring higher sensitivity thresholds and full circuit isolation!

Description

 

Technical Information
Range Circpro MK Sentry
Sensitivity 100 mA
Product RCD
Voltage 230 V
Pole Configuration Double Pole (2P)
Current Rating 63A
Rcd Sensitivity 100 mA
Number Of Poles Double Pole (2P)
Number Of Modules 2
Delivery

Delivery Costs

Our standard delivery charge to UK mainland addresses is £5.90 ex-VAT.

Take advantage of FREE* Delivery when you spend over £100 (per order) ex-VAT.

*Delivery charges to JE, GY, TR, BT, IM, IV, HS, KW, ZE and certain PA post codes are £12.00 ex-VAT.

Solar Panels, Batteries and Inverters

Due to their size all solar panels, batteries and inverters orders up to 50 qty will be despatched on a pallet and incur a £120** ex-VAT delivery charge.

**£180 ex VAT to JE, GY, TR, BT, IM, IV, HS, KW, ZE and certain PA post codes.

Click here to find out more.

Reviews